Home Up Search              

                     TARKSOL GREEN

 

 

 

 

 

Technical Information

Tarksol Sealproof

Non-VOC, High Solids, Solvent Based, Non-Yellowing, Acrylic Concrete, Sealing, Compound

  A Solvent Based Sealer with VOC's < 100 Grams/Liter

  Meets all State VOC (Volatile Organic Compound) Regulations

(New Jan. 1, 2005 Regulations and Future Regulations coming into Law)

  Designed for use as a gloss finish on new or aged concrete

  Use as a sealer/dustproofer on previously cured rough or smooth finished concrete surfaces. This Concrete Sealer contains 35% solids for long lasting durability and high gloss.

Product Description

Tarksol Sealproof provides protection and resistance to abrasion and staining. Tarksone is the solvent used

in Tarksol Conseal. Tarksone is a 0 VOC solvent that evaporates very quickly and exhibits a flash point over 140 deg F. Tarksol Sealproof dries very quickly to a hard glossy finish that is resistant to chemicals and abrasion.  This product is used for garage, basement, patio, industrial and repair shop concrete floors. A very high gloss and excellent durability.

  Advantages

 

·         Remains sprayable in freezing temperatures

·         Prevents surface crazing and cracking

·         Dries to a dust and tackproof state in 30 minutes quickly providing protection from rainfall, scuffing and foot traffic

·         Reduces final clean-up costs by protecting concrete from oil, grease and chemical spills and from mortar splashing adhesion

·         Second applications, after finial clean up, beautify concrete appearance with a lustroussheen and reduce after-occupancy maintenance costs

·         Treated surfaces are readily recoatable when necessary without sanding or scarification

·         Tarksol Conseal is compatible with most adhesives used for resilient floor coverings and concrete paints

·          Provides long term protection to concrete floors

Physical Properties

 

Solids---------------------------------------------35%

Boiling Point °F (Initial - Final)  -------------133°F (56°C)

Specific Gravity (H2O = 1)---------------------0.79

Vapor Pressure (mm Hg@70°F)--------------186

Vapor Density (Air = 1)------------------------2

Evaporation Rate (Butyl Acetate = 100)-----14.5

Solubility in Water------------------------------Not soluble

Appearance---------------------------------------Water White Colorless Liquid

Odor-----------------------------------------------Ether/Acrylic

Flash Point ° F (PMCC.)------------------------147°F (64°C) Pensky Marten Closed Cup (Electronic Ignition)

Percent Volatile---------------------------------65%

VOC----------------------------------------------90% is not a VOC under Federal & State Regulations.

                                                                             This product is a 10% VOC  

Use Instructions

  Site environmental conditions, substrate conditions and construction have a major effect on product selection, application methods, procedures and rates, appearance and performance. Product literature provides general information applicable to some or most conditions. However, an adequate site test application by the purchaser or installer in advance of field scale use is mandatory, to verify that product and quantities can be satisfactorily applied and will achieve desired appearance and performance under intended use conditions. 

  Low pressure spray application provides the best results; however, product can be applied with brushes or rollers. Spray apparatus should be equipped with chemically resistant hoses and gaskets. Larger areas are most economically treated with power sprayers.

  Do not thin or dilute

  Applications

Application rates vary with substrate conditions.

Approximate rates for curing is 250 square feet per gallon

Approximate rate for sealing is 300 square feet per gallon

Application equipment should be cleaned with solvents (Tarksol Biomass 60 or Tarksol HTF-85B environmental solvents are suggested).

 

Freshly Placed Concrete

Previously Cured Concrete

Maintenance

 

Apply immediately following finial finish and disappearance of surface water sheen. It is suggested to allow concrete to cure prior to application.  Tarksol Conseal is recommended as a curing compound however, Sealproof can be used.

 

Remove all dirt, oil, grease, paint or foreign cure residue with Tarksol Super Strip or Tarksol Oilsolv (environmental cleaners) and clean with a 10% caustic solution.

 

Wipe up all chemical, solvent or petroleum spills as soon as possible

 

Apply to the point of saturation and appearance of continuous surface film

 

Rinse thoroughly with clean water and squeegee off excess water.

 

Remove all dirt and debris by sweeping

 

Concrete should be damp but not wet. Avoid over application, puddles or runs

 

Allow surface to dry 24-48 hours prior to first application

 

Wash and buff periodically to help maintain surface luster

 

For maximum sealing and dustproffing benefits, apply a second coat of Tarksol  Sealproof after finial clean-up and concrete is dry

 

Use moisture meter or adequate material test to verify satisfactory adhesion and appearance

 

Clean damaged coating areas promptly and recoat

 

Apply a second application in 24 hours

 

Precautions

  Do not use on concrete slabs with inadequately drained subgrade, Treated surfaces to be covered with concrete or plaster, and/or surfaces subject to hydrostatic water pressures.

  Coating delamination (blistering) may occur if applied prior to allowing all surface bleed water to fully evaporate. Moisture saturated subgrade or a moisture barrier placed beneath the slab to be cured and/or sealed may increase the risk of coating delamination.

  Do not use with other floor sealers, treatments, bondbreakers or adhesives without prior site test to determine compatibility and adhesion.

  Any variations in concrete surface density may be highlighted by surface mottling after product application. Make test application to determine performance and appearance acceptability

  Do not use around sparks or open flame. Provide adequate ventilation.

  Treated surfaces may be slippery prior to drying and when wet with water or liquids after drying.

  When used in exterior applications, coated surfaces will slowly oxidize in time, necessitating reapplication.

  Patent Notice

Tarksol 97 is made under U.S. Patent numbers 5,112,516,  5,393,451, and 5,498,805. Tarksone is made under patent pending.

 

 

                         

 

 

 

 

 

 